The purpose of this Service Calibration is to calibrate the nominal
advance of the media. This calibration is necessary to control the
exact movement on the media type that will be used (upto 2) in order
to avoid print quality problems like banding.
Perform the Advance Calibration whenever:
Banding is detected in prints.
Printheads Diagnostic is OK.
Perform the Advance Calibration as follows:
In the Service Calibrations submenu, scroll to "Advance calibration"
and press Enter.
When the following message appears on the front panel, select "Create
pattern" and press Enter.
If media is not loaded, the following message appears on the front
panel and you must load media into the Printer.
The Printer will start to print the Accuracy Calibration Pattern
and the following message will be displayed on the front panel:
The following drawing shows you the pattern that will be printed:
In order to measure the pattern that has been printed, load the
pattern into the Printer with the printed side up and with the dotted
line at the top (that is, rotated 90º).
Re-enter the Advance Calibration and select "Measure pattern"
and press Enter.
The Printer will measure the alignment marks using the line sensor
on the Carriage Assembly. The following message will be displayed
while the Printer measures the pattern:
Once the calibration is completed, the following message will be
displayed: