2. Service Station Calibration
The purpose of this Service Calibration is to calibrate the Service Station in relation to the Carriage Assembly.
Perform the Service Station Calibration whenever:
Perform the Service Station Calibration as follows:
1. In the Service Calibrations submenu, scroll to "Service Station Calibration" and press Enter.
![]()
2. When the following message appears on the front panel, you must select whether you would like to continue with the calibration by pressing the Enter key. Press Back or Cancel to exit the calibration.
![]()
3. The Printer will start to calibrate the Service Station. Once the Service Station has been calibrated, the results will be displayed on the Front Panel. Press any key on the Front Panel to finish the calibration.
![]()
4. Once the calibration is completed, OK will be displayed on the Front Panel.
![]() |
|||||||||||||||||||||||||||||
|