7. Vacuum Calibration
The purpose of this Service Calibration is to set the default nominal and real values of the Vacuum Fan.
This Service Calibration should ONLY be performed when the Vacuum Fan has been replaced.
Perform the Vacuum Calibration as follows:
1. In the Service Calibrations submenu, scroll to "Vacuum Calibration" and press Enter.
![]()
2. When the following message appears on the front panel, you must select whether you would like to continue with the calibration by pressing the Enter key. Press Back or Cancel to exit the calibration.
![]()
3. The Printer will set the default nominal and real values of the Vacuum Fan.
![]()
4. Once the calibration is completed, OK will be displayed on the Front Panel.
![]() ![]() |
|||||||||||||||||||||||||||||
|